Bengaluru

'securezone brandsecure zones'

Items tagged with 'securezone brandsecure zones'

product image
Fire Alarm System

An optical smoke detector or photo-electric alarm works on the light scattering principle. The sensor chamber checks for smoke particles after every 10 seconds with the help of a pulsed infrared LED beam. These smoke detectors indicate a fire in non-smoking zones. They are used widely by commercial and industrial buildings as a safety measure. A commercial smoke detector sends a signal to the fire control panel while household fire alarms give audible or visual alarm from the detector. Smoke detectors are disc-shaped set up in plastic enclosures. The process of smoke detection takes place either through ionization or the photoelectric process. The detectors can use either of the two sensing methods. Domestic smoke detectors are interlinked and if one of them detects smoke, all the alarms trigger altogether even if the household power has gone out. Smoke detectors are used mostly in hospitals, gyms, office buildings, industries, malls and commercial buildings. How do Optical Smoke Detectors work? Smoke detectors work by detecting smoke in the first few seconds of the incident and send the signal to the fire control alarm panel. The types of detectors vary depending on the indicated fire that they detect. It also depends on the detection principle. Smoke, heat and flame are three main indicators of fire. The process used for detecting smoke is based on the light- scattering principle. When there is fire, smoke particles enter the optical chamber of smoke detectors. The LED light refracts and scatters on a photodiode. Then, the optical smoke detector sends the fire alarm signal to the control panel.

Send Message
product image
Fire Alarm System

A 4 Zone Fire Alarm Panel is a fire detection system designed to monitor and control up to four separate areas or zones within a building or premises. It is a more advanced fire alarm panel compared to a 2-zone system, offering greater flexibility for larger buildings or areas with multiple distinct fire risks. Each zone can be independently monitored for fire hazards, and the panel will alert the occupants or operators to any fire-related incidents in the designated zones. Key Features of a 4 Zone Fire Alarm Panel: Four Zone Monitoring: The 4-zone panel can monitor and control four separate zones in a building or premises. Each zone can consist of a set of smoke detectors, heat detectors, manual call points, or other fire detection devices. The four zones allow for greater flexibility, making the panel suitable for larger buildings where fire risks are spread across different areas, such as floors, wings, or sections of a building. Fire Detection Devices: The panel is connected to a variety of fire detection devices: Smoke detectors: Detect smoke particles in the air, indicating the potential presence of a fire. Heat detectors: Activate the alarm when a fire causes the temperature in an area to exceed a certain threshold. Manual call points: Allow people to manually trigger the alarm if they spot a fire. Gas detectors: Some panels may support additional detectors for gas hazards, such as carbon monoxide. Audible and Visual Alarms: When the fire alarm panel detects a fire or hazard, it triggers both audible alarms (siren, bell, or horn) and visual alarms (flashing lights or beacons) to alert the building’s occupants to evacuate the premises immediately. These alarms will also include a signal indicating which of the four zones has been activated, helping emergency responders quickly identify the location of the fire. Zone Status Indicators: A 4 Zone Fire Alarm Panel typically has indicator lights or digital displays for each of the four zones, showing their status (e.g., normal, alarm, fault, or active). These visual indicators help operators quickly identify which zone has a fire or fault, improving response time. The status indicators are often color-coded (e.g., green for normal, red for alarm) to help users quickly understand the system’s condition. Manual and Automatic Alarm Activation: The fire alarm panel can be triggered automatically by connected detectors (smoke or heat sensors) or manually by using a manual call point, where anyone who detects a fire can activate the alarm. In case of an alarm, the panel will display the specific zone where the alarm has been triggered. Test and Reset Functions: The panel includes test functions to ensure that all detectors and devices are functioning correctly. After an alarm event, a reset function is used to clear the alarm condition once the issue has been addressed, or in the case of a false alarm. Battery Backup: To ensure the system continues to function during power outages, the panel is typically equipped with a battery backup. This ensures that the fire alarm system remains operational even if the main electrical supply is interrupted. Compliance with Fire Safety Standards: A 4 Zone Fire Alarm Panel is designed to comply with local or international fire safety regulations, such as the BS 5839 standard in the UK, NFPA in the US, or similar codes in other countries. The system must meet rigorous testing requirements to ensure it performs reliably during an emergency. Expansion Capability: Some 4-zone panels can be connected to additional panels to expand the system if more zones are required. This allows for flexibility and scalability in larger buildings. Networking and Integration: The panel may also be integrated with other safety and emergency systems, such as sprinkler systems, emergency lighting, public address systems, or ventilation systems. Integration ensures that when an alarm is triggered, other safety measures (like sprinklers or emergency exits) can be activated automatically to help contain the fire.

Send Message
product image
Fire Alarm System

A 2 Zone Fire Alarm Panel is a fire detection and alarm system designed to monitor and control fire alarm devices in two distinct areas or zones of a building or premises. It is an essential safety feature for smaller buildings or areas where fire risks are present in different sections, allowing each zone to be independently monitored for smoke, heat, or fire signals. The panel alerts personnel to the presence of a fire within a designated zone, enabling a swift response to mitigate damage and ensure occupant safety. Key Features of a 2 Zone Fire Alarm Panel: Dual Zone Monitoring: The 2 zone designation means that the panel is capable of independently monitoring two distinct areas of a building. These zones could be different rooms, floors, or wings of a building. Each zone will have its own set of detectors, such as smoke detectors, heat detectors, or manual call points, linked to the alarm panel. The system will activate visual or audible alarms, such as flashing lights or sirens, when a fire hazard is detected in either of the zones. Fire Detection Devices: The panel can be connected to various types of fire detection devices, including: Smoke detectors: Detect the presence of smoke in the air, which may indicate a fire. Heat detectors: Trigger an alarm if the temperature exceeds a certain threshold, often used in areas where smoke detectors might be less effective (like kitchens). Manual call points: Allow individuals to manually trigger the alarm if they notice a fire. Carbon monoxide detectors (optional): Can be included to monitor for toxic gases. Audible and Visual Alarms: When a fire or hazard is detected, the fire alarm panel triggers audible alarms (like sirens or bells) and/or visual alarms (like flashing lights or beacons). This alerts building occupants to evacuate immediately and take appropriate action. Indicator Lights for Zone Status: A 2 Zone Fire Alarm Panel typically has indicator lights for each zone to show the current status (e.g., normal, alarm, fault, or active). These lights help operators identify which zone has triggered an alarm and allows for faster identification of the fire's location. Test and Reset Functions: The fire alarm panel includes a test button for checking the functionality of the connected devices, ensuring they are working correctly. There is also a reset function that allows users to reset the system after an alarm event, such as a false alarm or maintenance. Manual and Automatic Alarm Activation: The fire alarm system may activate automatically upon detecting a fire condition (from smoke or heat). It also provides the ability for manual activation, where a person can trigger the alarm from a manual call point. Battery Backup: To ensure continuous operation in the event of a power failure, most fire alarm panels include a battery backup. This ensures that the fire alarm system remains functional even if the main electrical supply is interrupted. Status Indicators and Alarms: The panel provides real-time indicators for system health, including the power status, battery status, and trouble conditions (e.g., faults in the wiring or communication with detectors). These alerts are critical for ensuring the system remains operational. Compliance with Fire Safety Regulations: The fire alarm system is designed to comply with local fire safety codes and regulations. These regulations often require fire alarm systems to be tested, maintained, and certified for safety and reliability. Integration with Other Safety Systems: A 2-zone fire alarm panel may integrate with other safety or building management systems, such as sprinkler systems, emergency lighting, and evacuation systems. When the fire alarm is triggered, it may automatically activate other systems to mitigate the impact of the fire.

Send Message
product image
Fire Extingusihers

Secure Zone's new CO2 extinguisher is perfect for fires involving flammable liquids such as petrol and oil. Product Overview A typical CO2 extinguisher weighs a staggering 18.5 kgs, making it extremely difficult to carry and operate. CO2 is also stored at very low temperatures, often causing freeze burns on the user’s hands in the process of activation. The revolutionary new squeeze grip activation, removes all risk of freeze burn, and ensures that the user can rapidly put the extinguisher to use against a fire. An ergonomically designed handle at the center of the extinguisher distributes the load evenly to the key arm muscles, making the extinguisher easier to carry. Product Features Introduction: CO2 extinguishers are the perfect weapon against large, hard to fight Class B,C and electrically started fires. CO2 extinguishers offer higher storage capacity than regular sized CO2 extinguishers. The squeeze grip activation feature ensures that the extinguisher can be activated rapidly in an emergency. Easy snap safety seal: A completely tamper proof safety seal that can be broken in seconds. Squeeze grip: The rapid squeeze grip activation eliminates all risk of freeze burns. An ergonomically designed handle makes it remarkably easy to carry. Compatibility: Safe for use on sensitive equipment. Simplicity in handling: The easy grip plastic handle aids simplicity in handling. Controllable discharge: A simple squeeze grip activation mechanism allows you to control the discharge and optimise use of the extinguishing agent. 1 year Warranty: The 1 year Warranty means Secure Zone is looking out for the health of your fire safety products. Protective covering: The valve features a protective covering. Ready/used indicator: A mechanical device that shows the current status of the extinguisher. Hosepipe: Superior grade rubber is far more flexible than the normal rubber used in most hosepipes. It is also far less prone to cracks. Highest standards: Virtually every Alternate range of extinguisher IS Certification is under process. Technical Specifications Size Variant - 4.5Kg Gross Weight: 16.02kg Empty Weight: 11.50kg Can Height: 715mm Diameter: 139.7mm Discharge time: Approx.10 Secs Discharge Mechanism : Squeeze Grip Type Range : 2mts Applicable on: B,C and electrically started fires Ratings: 34B Can Construction :Hot Spinning Process Valve Construction : Forging & Machining Internal Coating of Can : Not Applicable External Coating of Can : Epoxy Polyster Powder Coating Sheet metal thickness: 4.00MM Certifications: Conforms to BIS Standards Warranty : 1 Year

Send Message
product image
Fire Extingusihers

Secure Zone's new CO2 extinguisher is perfect for fires involving flammable liquids such as petrol and oil. Product Overview A typical CO2 extinguisher weighs a staggering 18.5 kgs, making it extremely difficult to carry and operate. CO2 is also stored at very low temperatures, often causing freeze burns on the user’s hands in the process of activation. The revolutionary new squeeze grip activation, removes all risk of freeze burn, and ensures that the user can rapidly put the extinguisher to use against a fire. An ergonomically designed handle at the center of the extinguisher distributes the load evenly to the key arm muscles, making the extinguisher easier to carry. Product Features Introduction: CO2 extinguishers are the perfect weapon against large, hard to fight Class B,C and electrically started fires. CO2 extinguishers offer higher storage capacity than regular sized CO2 extinguishers. The squeeze grip activation feature ensures that the extinguisher can be activated rapidly in an emergency. Easy snap safety seal: A completely tamper proof safety seal that can be broken in seconds. Squeeze grip: The rapid squeeze grip activation eliminates all risk of freeze burns. An ergonomically designed handle makes it remarkably easy to carry. Compatibility: Safe for use on sensitive equipment. Simplicity in handling: The easy grip plastic handle aids simplicity in handling. Controllable discharge: A simple squeeze grip activation mechanism allows you to control the discharge and optimise use of the extinguishing agent. 1 year Warranty: The 1 year Warranty means Secure Zone is looking out for the health of your fire safety products. Protective covering: The valve features a protective covering. Ready/used indicator: A mechanical device that shows the current status of the extinguisher. Hosepipe: Superior grade rubber is far more flexible than the normal rubber used in most hosepipes. It is also far less prone to cracks. Highest standards: Virtually every Alternate range of extinguisher IS Certification is under process. Technical Specifications Size Variant - 2Kg Gross Weight: 8.25kg Empty Weight: 6.25kg Can Height: 580MM, Diameter: 108MM, Discharge time: Approx. 11 Secs Discharge Mechanism : Squeeze Grip Type Range : 2mts Applicable on: B,C and electrically started fires Ratings: 13B Can Construction :Hot Spinning Process Valve Construction : Forging & Machining Internal Coating of Can : Not Applicable External Coating of Can : Epoxy Polyster Powder Coating Certifications: Conforms to BIS Standards Sheet metal thickness: 4.00MM Warranty : 1 Year

Send Message
product image
Fire Extingusihers

Secure Zone's ABC Dry Powder Fire Extinguishers are effective against all classes of fires i.e Class A, Class B, Class C and Electrically started fires. Secure Zone's ABC Dry Powder Fire extinguishers contain a specialised Mono Ammonium Phosphate (MAP) Powder that kills fires in no time. Product Overview Using the wrong extinguisher on a fire can be very dangerous. And often, there isn’t enough time to decide which extinguisher to use. In such cases, the consequences often prove fatal. Secure Zone's range of ABC extinguishers are effective against Class A, B and C fires as well as Electrical fires. They take the guesswork and confusion out of choosing an extinguisher and save valuable time in the face of the fatally dangerous enemy called fire. ​ Secure Zone's ABC extinguishers are built for speed, power and reliability. A simple two-step activation mechanism allows you to fight the fire within seconds. A high concentration of Mono Ammonium Phosphate maximizes the fire fighting power available to you. And stringent quality control and multiple point testing systems ensure that when you are faced with a fire, these extinguishers will deliver. Product Features Introduction: Using the wrong extinguisher on the wrong class of fire can have fatal consequences. Alternate range of ABC Powder based MAP extinguishers work on all types of fires, including electrical fires, and are ideal for applications where one is unsure of what type of fire may arise. Easy snap safety seal: The safety seal that can be broken in seconds. Simplicity in handling: The easy grip plastic handle aids simplicity in handling. Controllable discharge: A simple squeeze grip activation mechanism allows you to control the discharge and optimise use of the extinguishing agent. Quality control systems: Comes with BIS certification, and conforms to ISI standards. Comprehensive Helium Tests and Leak Tests also guarantee that the products you buy are manufactured according to the world's most stringent quality standards. 3 year Warranty: The 3 year Warranty means Secure Zone is looking out for the health of your fire safety products. Works on all the types of fire: Fights Class A, B, C and Electrically started fires. Extinguishing agent: A combination of mono ammonium phosphate (MAP) and ammonium sulphate, ABC Dry Powder not only cuts off oxygen supply to the fire but also interferes with the chemical reaction necessary to sustain a fire. Highest standards: Virtually every Alternate range of extinguisher IS Certification is under process. Technical Specifications Size Variant - 2Kg ​Gross Weight: 3.52Kg Empty Weight: 1.52Kg Can Height: 352mm Diameter: 108mm Discharge time: ​Approx.9 Secs Discharge Mechanism : Squeeze Grip Range: Not Less Than 2 Meters Applicable on: Class A,B,C and electrically started Fire A Rating: 1A, B Rating: 13B Can Construction : Mig welded, Valve Construction : Forging & Machining Internal Coating of Can : NA External Coating of Can : Epoxy Polyester Powder coating Sheet metal thickness: 1.60MM Certifications: Conforms to BIS Standards Warranty : 3 Year

Send Message
product image
Fire Extingusihers

Secure Zone's ABC Dry Powder Fire Extinguishers are effective against all classes of fires i.e Class A, Class B, Class C and Electrically started fires. Secure Zone's ABC Dry Powder Fire extinguishers contain a specialised Mono Ammonium Phosphate (MAP) Powder that kills fires in no time. Product Overview Using the wrong extinguisher on a fire can be very dangerous. And often, there isn’t enough time to decide which extinguisher to use. In such cases, the consequences often prove fatal. Secure Zone's range of ABC extinguishers are effective against Class A, B and C fires as well as Electrical fires. They take the guesswork and confusion out of choosing an extinguisher and save valuable time in the face of the fatally dangerous enemy called fire. ​ Secure Zone's ABC extinguishers are built for speed, power and reliability. A simple two-step activation mechanism allows you to fight the fire within seconds. A high concentration of Mono Ammonium Phosphate maximizes the fire fighting power available to you. And stringent quality control and multiple point testing systems ensure that when you are faced with a fire, these extinguishers will deliver. Product Features Introduction: Using the wrong extinguisher on the wrong class of fire can have fatal consequences. Alternate range of ABC Powder based MAP extinguishers work on all types of fires, including electrical fires, and are ideal for applications where one is unsure of what type of fire may arise. Easy snap safety seal: The safety seal that can be broken in seconds. Simplicity in handling: The easy grip plastic handle aids simplicity in handling. Controllable discharge: A simple squeeze grip activation mechanism allows you to control the discharge and optimise use of the extinguishing agent. Quality control systems: Comes with BIS certification, and conforms to ISI standards. Comprehensive Helium Tests and Leak Tests also guarantee that the products you buy are manufactured according to the world's most stringent quality standards. 3 year Warranty: The 3 year Warranty means Secure Zone is looking out for the health of your fire safety products. Works on all the types of fire: Fights Class A, B, C and Electrically started fires. Extinguishing agent: A combination of mono ammonium phosphate (MAP) and ammonium sulphate, ABC Dry Powder not only cuts off oxygen supply to the fire but also interferes with the chemical reaction necessary to sustain a fire. Highest standards: Virtually every Alternate range of extinguisher IS Certification is under process. Technical Specifications Size Variant - 1Kg ​Gross Weight: 2.10Kg Empty Weight: 1.10kg Can Height: 315mm Diameter: 86.5mm Discharge time: Approx.8 Secs Discharge Mechanism : Squeeze Grip Type Range: Not Less Than 2 Meters Applicable on: Class A,B,C and electrically started Fire A Rating: 1A, B Rating: 8B Can Construction : Mig welded, Valve Construction : Forging & Machining Internal Coating of Can : NA External Coating of Can : Epoxy Polyester Powder coating Sheet metal thickness: 1.60MM Certifications: Conforms to BIS Standards Warranty : 3 Year