Indore

'properly maintained'

Items tagged with 'properly maintained'

product image
SIGNAGES

An exit sign is a pictogram or short text in a public facility (such as a building, aircraft, or boat) denoting the location of the closest emergency exit to be used in case of fire or other emergency that requires rapid evacuation. Most relevant codes (fire, building, health, or safety) require exit signs to be permanently lit. Exit signs are designed to be absolutely unmistakable and understandable to anyone. right icon Edge Lit Long Life LED's right icon Maintained / Non- Maintained typed right icon Transparent Acrylic panel with single / double side option right icon Status LED indicator (Main/ battery back Back-up) right icon Wall /Ceiling mounted option right icon 20 LED's (14 nos. for main's and 14 nos. for power back up) right icon CRCA housing duly powder coated finish right icon Screen printing /Engraved as per approved pictographs

Send Message
product image
SIGNAGES

An exit sign is a pictogram or short text in a public facility (such as a building, aircraft, or boat) denoting the location of the closest emergency exit to be used in case of fire or other emergency that requires rapid evacuation. Most relevant codes (fire, building, health, or safety) require exit signs to be permanently lit. Exit signs are designed to be absolutely unmistakable and understandable to anyone. right icon Edge Lit Long Life LED's right icon Maintained / Non- Maintained typed right icon Transparent Acrylic panel with single / double side option right icon Status LED indicator (Main/ battery back Back-up) right icon Wall /Ceiling mounted option right icon 20 LED's (14 nos. for main's and 14 nos. for power back up) right icon CRCA housing duly powder coated finish right icon Screen printing /Engraved as per approved pictographs

Send Message
product image
SIGNAGES

An exit sign is a pictogram or short text in a public facility (such as a building, aircraft, or boat) denoting the location of the closest emergency exit to be used in case of fire or other emergency that requires rapid evacuation. Most relevant codes (fire, building, health, or safety) require exit signs to be permanently lit. Exit signs are designed to be absolutely unmistakable and understandable to anyone. right icon Edge Lit Long Life LED's right icon Maintained / Non- Maintained typed right icon Transparent Acrylic panel with single / double side option right icon Status LED indicator (Main/ battery back Back-up) right icon Wall /Ceiling mounted option right icon 20 LED's (14 nos. for main's and 14 nos. for power back up) right icon CRCA housing duly powder coated finish right icon Screen printing /Engraved as per approved pictographs

Send Message
product image
Fire Alarm System

The Conventional heat detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel. The Conventional rate of rise heat detector uses thermal component to detect the temperature changing in the environment. It can enable fire alarm when the temperaturedifference achieved the setting rate of rise temperature valuereach the setting fixed value. It has a stable and reliable workingperformance. Two LEDs on each detector provide local 360 visible alarm Indication. They flash every six seconds indicating that power Is applied and the detector is working properly. The LEDs latch On in alarm. LEDs will be off when a trouble condition exists that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption. The detector that initiated the alarm condition will have its red LED and relays latched until reset by panel.

Send Message
product image
Fire Alarm System

A 2 Zone Fire Alarm Panel is a fire detection and alarm system designed to monitor and control fire alarm devices in two distinct areas or zones of a building or premises. It is an essential safety feature for smaller buildings or areas where fire risks are present in different sections, allowing each zone to be independently monitored for smoke, heat, or fire signals. The panel alerts personnel to the presence of a fire within a designated zone, enabling a swift response to mitigate damage and ensure occupant safety. Key Features of a 2 Zone Fire Alarm Panel: Dual Zone Monitoring: The 2 zone designation means that the panel is capable of independently monitoring two distinct areas of a building. These zones could be different rooms, floors, or wings of a building. Each zone will have its own set of detectors, such as smoke detectors, heat detectors, or manual call points, linked to the alarm panel. The system will activate visual or audible alarms, such as flashing lights or sirens, when a fire hazard is detected in either of the zones. Fire Detection Devices: The panel can be connected to various types of fire detection devices, including: Smoke detectors: Detect the presence of smoke in the air, which may indicate a fire. Heat detectors: Trigger an alarm if the temperature exceeds a certain threshold, often used in areas where smoke detectors might be less effective (like kitchens). Manual call points: Allow individuals to manually trigger the alarm if they notice a fire. Carbon monoxide detectors (optional): Can be included to monitor for toxic gases. Audible and Visual Alarms: When a fire or hazard is detected, the fire alarm panel triggers audible alarms (like sirens or bells) and/or visual alarms (like flashing lights or beacons). This alerts building occupants to evacuate immediately and take appropriate action. Indicator Lights for Zone Status: A 2 Zone Fire Alarm Panel typically has indicator lights for each zone to show the current status (e.g., normal, alarm, fault, or active). These lights help operators identify which zone has triggered an alarm and allows for faster identification of the fire's location. Test and Reset Functions: The fire alarm panel includes a test button for checking the functionality of the connected devices, ensuring they are working correctly. There is also a reset function that allows users to reset the system after an alarm event, such as a false alarm or maintenance. Manual and Automatic Alarm Activation: The fire alarm system may activate automatically upon detecting a fire condition (from smoke or heat). It also provides the ability for manual activation, where a person can trigger the alarm from a manual call point. Battery Backup: To ensure continuous operation in the event of a power failure, most fire alarm panels include a battery backup. This ensures that the fire alarm system remains functional even if the main electrical supply is interrupted. Status Indicators and Alarms: The panel provides real-time indicators for system health, including the power status, battery status, and trouble conditions (e.g., faults in the wiring or communication with detectors). These alerts are critical for ensuring the system remains operational. Compliance with Fire Safety Regulations: The fire alarm system is designed to comply with local fire safety codes and regulations. These regulations often require fire alarm systems to be tested, maintained, and certified for safety and reliability. Integration with Other Safety Systems: A 2-zone fire alarm panel may integrate with other safety or building management systems, such as sprinkler systems, emergency lighting, and evacuation systems. When the fire alarm is triggered, it may automatically activate other systems to mitigate the impact of the fire.

Send Message
product image
Fire Extingusihers

The Lifeguard 4kg Clean Agent Fire Extinguisher is designed for use in environments where sensitive equipment or materials need to be protected from fire without causing damage or residue. Here’s a breakdown of its key features and uses: Key Features of a 4kg Clean Agent Fire Extinguisher: Clean Agent: A clean agent fire extinguisher uses a non-toxic, non-conductive gas to suppress fires. The agent is designed to leave no residue, making it ideal for sensitive electronic equipment, data centers, and areas with valuable or delicate machinery. The clean agent most commonly used is FM-200, although other agents like Novec 1230 can also be used. These extinguishers are designed to be effective in extinguishing Class A (ordinary combustibles), Class B (flammable liquids), and Class C (electrical) fires. 4kg Capacity: The 4 kg indicates the amount of clean agent in the fire extinguisher. This is a medium-sized extinguisher, typically used in office settings, server rooms, or small warehouses where the risk of electrical fires is present. Fire Classes: Class A: Ordinary combustible materials such as wood, paper, and cloth. Class B: Flammable liquids like gasoline, oils, and paints. Class C: Electrical fires, such as fires involving equipment, wiring, or circuits. Discharge Time and Range: Clean agent fire extinguishers typically have a discharge time of around 8-10 seconds, depending on the specific product. The discharge range can vary but is generally around 3-4 meters. Non-Residue Effect: One of the major benefits of clean agent extinguishers is that they leave no residue, which is critical in environments with valuable electronics, such as data centers, computer rooms, laboratories, and aircraft. This also means that there is no cleanup required after the fire is extinguished. Safety: Non-toxic: Clean agents are safe for humans in occupied spaces, provided the room is well-ventilated after discharge. Non-conductive: Safe to use on electrical fires without the risk of electrocution. Application: Clean agent extinguishers are typically used in places where other types of extinguishers, such as water or CO2, may cause damage to the property or equipment. These include: Data Centers: Protecting servers and networking equipment. IT Rooms: Safeguarding computers and network infrastructure. Medical Facilities: Areas where sensitive equipment needs protection. Electrical Rooms: Safeguarding against electrical fires without the risk of damage. Maintenance: As with all fire extinguishers, it’s important to inspect the Lifeguard 4kg Clean Agent Fire Extinguisher regularly (e.g., monthly) to ensure it is properly pressurized, the nozzle is unobstructed, and the extinguisher is in good working condition. Check the pressure gauge and ensure the extinguisher is not expired or damaged.

Send Message

Still searching for
properly maintained?