Raipur

'door 2'

Items tagged with 'door 2'

product image
Fire Alarm System

A 2 Zone Fire Alarm Panel is a fire detection and alarm system designed to monitor and control fire alarm devices in two distinct areas or zones of a building or premises. It is an essential safety feature for smaller buildings or areas where fire risks are present in different sections, allowing each zone to be independently monitored for smoke, heat, or fire signals. The panel alerts personnel to the presence of a fire within a designated zone, enabling a swift response to mitigate damage and ensure occupant safety. Key Features of a 2 Zone Fire Alarm Panel: Dual Zone Monitoring: The 2 zone designation means that the panel is capable of independently monitoring two distinct areas of a building. These zones could be different rooms, floors, or wings of a building. Each zone will have its own set of detectors, such as smoke detectors, heat detectors, or manual call points, linked to the alarm panel. The system will activate visual or audible alarms, such as flashing lights or sirens, when a fire hazard is detected in either of the zones. Fire Detection Devices: The panel can be connected to various types of fire detection devices, including: Smoke detectors: Detect the presence of smoke in the air, which may indicate a fire. Heat detectors: Trigger an alarm if the temperature exceeds a certain threshold, often used in areas where smoke detectors might be less effective (like kitchens). Manual call points: Allow individuals to manually trigger the alarm if they notice a fire. Carbon monoxide detectors (optional): Can be included to monitor for toxic gases. Audible and Visual Alarms: When a fire or hazard is detected, the fire alarm panel triggers audible alarms (like sirens or bells) and/or visual alarms (like flashing lights or beacons). This alerts building occupants to evacuate immediately and take appropriate action. Indicator Lights for Zone Status: A 2 Zone Fire Alarm Panel typically has indicator lights for each zone to show the current status (e.g., normal, alarm, fault, or active). These lights help operators identify which zone has triggered an alarm and allows for faster identification of the fire's location. Test and Reset Functions: The fire alarm panel includes a test button for checking the functionality of the connected devices, ensuring they are working correctly. There is also a reset function that allows users to reset the system after an alarm event, such as a false alarm or maintenance. Manual and Automatic Alarm Activation: The fire alarm system may activate automatically upon detecting a fire condition (from smoke or heat). It also provides the ability for manual activation, where a person can trigger the alarm from a manual call point. Battery Backup: To ensure continuous operation in the event of a power failure, most fire alarm panels include a battery backup. This ensures that the fire alarm system remains functional even if the main electrical supply is interrupted. Status Indicators and Alarms: The panel provides real-time indicators for system health, including the power status, battery status, and trouble conditions (e.g., faults in the wiring or communication with detectors). These alerts are critical for ensuring the system remains operational. Compliance with Fire Safety Regulations: The fire alarm system is designed to comply with local fire safety codes and regulations. These regulations often require fire alarm systems to be tested, maintained, and certified for safety and reliability. Integration with Other Safety Systems: A 2-zone fire alarm panel may integrate with other safety or building management systems, such as sprinkler systems, emergency lighting, and evacuation systems. When the fire alarm is triggered, it may automatically activate other systems to mitigate the impact of the fire.

Send Message
product image
Fire Extingusihers

Secure Zone's new CO2 extinguisher is perfect for fires involving flammable liquids such as petrol and oil. Product Overview A typical CO2 extinguisher weighs a staggering 18.5 kgs, making it extremely difficult to carry and operate. CO2 is also stored at very low temperatures, often causing freeze burns on the user’s hands in the process of activation. The revolutionary new squeeze grip activation, removes all risk of freeze burn, and ensures that the user can rapidly put the extinguisher to use against a fire. An ergonomically designed handle at the center of the extinguisher distributes the load evenly to the key arm muscles, making the extinguisher easier to carry. Product Features Introduction: CO2 extinguishers are the perfect weapon against large, hard to fight Class B,C and electrically started fires. CO2 extinguishers offer higher storage capacity than regular sized CO2 extinguishers. The squeeze grip activation feature ensures that the extinguisher can be activated rapidly in an emergency. Easy snap safety seal: A completely tamper proof safety seal that can be broken in seconds. Squeeze grip: The rapid squeeze grip activation eliminates all risk of freeze burns. An ergonomically designed handle makes it remarkably easy to carry. Compatibility: Safe for use on sensitive equipment. Simplicity in handling: The easy grip plastic handle aids simplicity in handling. Controllable discharge: A simple squeeze grip activation mechanism allows you to control the discharge and optimise use of the extinguishing agent. 1 year Warranty: The 1 year Warranty means Secure Zone is looking out for the health of your fire safety products. Protective covering: The valve features a protective covering. Ready/used indicator: A mechanical device that shows the current status of the extinguisher. Hosepipe: Superior grade rubber is far more flexible than the normal rubber used in most hosepipes. It is also far less prone to cracks. Highest standards: Virtually every Alternate range of extinguisher IS Certification is under process. Technical Specifications Size Variant - 4.5Kg Gross Weight: 16.02kg Empty Weight: 11.50kg Can Height: 715mm Diameter: 139.7mm Discharge time: Approx.10 Secs Discharge Mechanism : Squeeze Grip Type Range : 2mts Applicable on: B,C and electrically started fires Ratings: 34B Can Construction :Hot Spinning Process Valve Construction : Forging & Machining Internal Coating of Can : Not Applicable External Coating of Can : Epoxy Polyster Powder Coating Sheet metal thickness: 4.00MM Certifications: Conforms to BIS Standards Warranty : 1 Year

Send Message

Still searching for
door 2?